Features
- Provides GBIC-to-SFP interface connectivity
- Data rate independent, protocol transparent
- Greater flexibility and scalability
- Complete range of optical and copper plug-in interfaces available from MRV Communications
- Performs 2R data signal conditioning
- Supports SFP digital diagnostics as per SFF-8472
- SNMP manageable, MegaVision Web® supported
- Media conversion
- Signal boosting
- Lambda conversion
- CWDM
- DWDM
- OADM
EM316-GBICSFP - GBIC to SFP Media Converter Continuing to push the boundaries of media connectivity, the Fiber Driver® GBIC-to-SFP Media Module (EM316-GBICSFP) from MRV Communications is a data rate independent, single channel solution for linking GBIC and SFP interfaces. It defines a new level of deployment flexibility and inventory management, enabling the implementation of an extremely wide range of network infrastructure solutions from media conversion and signal boosting to lambda conversion, Wave Division Multiplexing (WDM) and Optical Add/Drop Multiplexing (OADM).
The GBIC-to-SFP Media Module offers plug-n-play ease of installation. Simply place the module into the Fiber Driver chassis, insert the GBIC and SFP transceivers required for the protocol and distance of the application, and connect to the network.
Because GBIC and SFP transceivers are portable they can be easily used again at a different location for a different application, maximizing the investment in equipment and reducing the need for on-hand inventory. MRV Communications provides a complete range of optical and copper plug-in interfaces for the EM316GBIC-SFP.
The GBIC-to-SFP Media Module is data rate independent and performs 2R - reshape and retransmit - conditioning of the data signal. Any protocol is supported, including Fast and Gigabit Ethernet, FDDI, ESCON, SONET (OC-3, OC-12, OC-48 and above), Fibre Channel (1 Gbps & 2 Gbps), Serial Digital Video Interface (SDI) SMPTPE-269 and SMTPE-292, DVB, HDTV (1.5 Gbps), and many others.
With an externally connected Mux/Demux unit such as the 4- or 8-channel Fiber Driver CWDM Passive Mux/Demux (EM316PA4N / EM316PA8N), the GBIC-to-SFP Media Module can be used as a WDM solution building block configured to the desired protocol/data rate and provided with GBICs or SFPs of the required wavelengths. Deployed along a WDM trunk at customer service points using MRV Communications' passive OADM technology, the GBIC-to-SFP Media Module can be used to create a sophisticated Add/Drop topology.
The GBIC-to-SFP Media Module is a hot swappable, single-slot module that can be placed in any powered Fiber Driver chassis. It fully supports the GBIC and SFP standards, including SFP digital diagnostics as per SFF-8472. Through the Fiber Driver Network Management Module, the EM316-GBICSFP is SNMP manageable and fully supported through the GUI of MegaVision Web®, MRV Communications' comprehensive Network Management System (NMS).
| GBIC-GA-RJ | GBIC 1000Base-TX, RJ-45, auto-negotiating, 1-100m | | | | | Gigabit Ethernet/Fibre Channel | | GBIC-SX | GBIC 1000Base-SX, MM, 850nm, 0-550m. | | | | | GBIC-MMX | GBIC 1000Base-SX,Extended MM, 1310nm, 2km. | | | | | GBIC-MMXSF | GBIC 1000Base-SX, Extended MM, 1310nm, Single Fiber 2km, SC-APC Connectors | | | | | GBIC-LX | GBIC 1000Base-LX, SM, 1310nm, 0-25km. | | | | | GBIC-ZX | GBIC 1000Base-ZX, SM, 1550nm, 0-95km. *Please inquire for longer distances. | | | | | CWDM Gigabit Ethernet/ Fibre Channel | | GBIC-CWZX-XX | GBIC 1000Base-ZX, SM CWDM,(XX=Wavelength 1470 - 1610nm), 30-80km. | | | | | SFP - Small Form Pluggable | | Single Fiber Bi-directional Dual W/L | | SFP-O3D-BX35 | SFP OC-3 or 100Base-BX, SM Single Fiber Simplex SC, TX: 1310nm, RX: 1550nm. 0-30km, with Digital Diagnostics. | | | | | SFP-O3D-BX53 | SFP OC-3 or 100Base-BX, SM Single Fiber Simplex SC, TX: 1550nm, RX: 1310nm. 0-30km, with Digital Diagnostics. | | | | | SFP-GD-BX34 | SFP 1000Base-BX, SM Single Fiber Simplex SC, TX: 1310nm, RX: 1490nm. 0-25km, with Digital Diagnostics. | | | | | SFP-GD-BX43 | SFP 1000Base-BX, SM Single Fiber Simplex SC, TX: 1490nm, RX: 1310nm. 0-25km, with Digital Diagnostics. | | | | | Ethernet Copper (RJ45) for Layer 0/1 Products | | SFP-GC | SFP supporting 1000Base-TX for Layer 0/1 devices | | | | | SFP-GA-RJ | SFP supporting 1000Base-TX for Layer 2 and higher devices | | | | | SFP-EFG | SFP supporting 10/100/1000Base-TX for Layer 0/1 devices (must be used in paris) | | | | | Copper Fire Wire | | | SFP-1394A | Copper Fire Wire with "A" Connector | | | | | SFP-1394B | Copper Fire Wire with "B" Connector | | | | | Fast Ethernet Multimode & Single-Mode (LC Connectors) | | SFP-F-SX | SFP 100Base-FX, MM, 1310nm, 0-2km. Same as SFP-MR2-M. | | | Please see the SFP OC-3 section for more Fast Ethernet SFP's | | | | | Gigabit Ethernet/Fibre Channel | | SFP-G-MMX | SFP 1000Base-SX, Extended MM, 1310nm, 0-2km. | | | | | SFP-G-LX | SFP 1000Base-LX, SM, 1310nm, 0-25km. | | | | | SFP-GD-LX | SFP 1000Base-LX, SM, 1310nm. 0-25km, with Digital Diagnostics. | | | | | SFP-GD-ELX | SFP 1000Base-ELX, SM, 1310nm, 0-35km, with Digital Diagnostics. | | | | | SFP-GD-XD | SFP 1000Base-XD, SM, 1550nm, 15-75km, with Digital Diagnostics. | | | | | SFP-GD-ZX | SFP 1000Base-ZX, SM, 1550nm, 35-95km, with Digital Diagnostics. | | | | | SFP-GD-EZX | SFP 1000Base-EZX, SM 1550nm, 45-125km, with Digital Diagnostics. | | | | | CWDM Gigabit Ethernet/Fibre Channel | | SFP-GDCWXD-XX | SFP 1000Base-XD, SM CWDM (XX=Wavelength 1470 - 1610nm), 50km, with Digital Diagnostics. | | | | | SFP-GDCWZX-XX | SFP 1000Base-ZX, SM CWDM (XX=Wavelength 1470-1610nm), 80km, CWDM with Digital Diagnostics. | | | | | SFP-GDCWEZX-XX | SFP 1000Base-EZX, SM CWDM (XX=Wavelength 14710-1610nm) 120km with Digial Diagnostics. | | | | | Fibre Channel Dual Rate (1&2Gbps) (LC Connectors) | | SFP-DGD-SX | SFP Dual Rate 1/2.1 Gbps SX, or 1000Base-SX GigE, MM, 850nm, 0-550m, with Digital Diagnostics. | | | | | Fast Ethernet OC-3 (LC Connectors) | | SFP-O3-M | SFP Fast Ethernet and OC-3, MM, 1310nm, 0-2km | | | | | SFP-O3-IR1 | SFP Fast Ethernet ELX or OC-3 IR 1, SM, up to 155/200Mbps, 1310nm, 0-30km | | | | | SFP-O3-LR1 | SFP Fast Ethernet EZX or OC-3 LR1, up to 155Mpbs, SM, 1310nm, 0-60km | | | | | SFP-O3D-LR1 | SFP Fast Ethernet XD or OC-3 LR1, up to 155Mbps, SM, 1310nm, 40km, with Digital Diagnostics. | | | | | SFP-O3D-LR2 | SFP Fast Ethernet EZX or OC-3 LR2, up to 155Mbps, 1550nm, SM, 40-116km, with Digital Diagnostics. | | | | | OC-12 (LC Connectors) | | SFP-DRO12D-IR1 | SFP Dual Rate OC-3/OC-12 IR1, 155/622Mbps, 1310nm, SM, 0-25km, with Digital Diagnostics. | | | | | SFP-O12D-LR1 | SFP OC-12 LR1, 622Mbps, 1310nm, SM, 20-50km, with Digital Diagnostics. | | | | | SFP-O12D-LR2 | SFP OC-12 LR2, 622Mbps, 1550nm, SM, 40-100km, with Digital Diagnostics. | | | | | OC-48 (LC Connectors) | | SFP-OC48-IR2 | SFP OC48 IR2, SM,1550nm, 0-60km | | | | | SFP-OC48-MMX | SFP OC48, Extended MM, 1310nm, 0-2km. | | | | | SFP-OC48D-SR1 | SFP OC48 SR1, 1310nm, SM, 0-20km, with Digital Diagnostics. | | | | | SFP-OC48D-IR1 | SFP OC48 IR1, SM, 1310nm, 0-30km with Digital Diagnostics. | | | | | SFP-OC48D-IR2 | SFP OC48 IR2, SM,1550nm, 0-60km with Digital Diagnostics. | | | | | SFP-OC48D-LR1 | SFP OC-48 LR1, SM 1310nm, 20-50km, with Digital Diagnostics | | | | | SFP-OC48D-LR2 | SFP OC-48 LR2, SM 1550nm, 35-100km, with Digital Diagnostics. | | | | | CWDM OC-48 (LC Connectors) | | SFP-48DCWIR-XX | SFP OC-48 IR, SM CWDM (XX=Wavelength 1470-1610nm), 50km, with Digital Diagnostics. | | | | | SFP-48DCWLR-XX | SFP OC-48 LR, SM CWDM (XX=Wavelength 1470-1610nm), 80 km, with Digital Diagnostics. | | Protocol Independent (LC Connectors) | | SFP-MR2-M | SFP Multirate 100-200Mbps, MM, 1310nm, 0-2km | | | | | SFP-MR27D-MMX | SFP Multi-rate 100-2700Mbps, Extended MM, 1310nm, 0-2km with Digital Diagnostics | | | | | SFP-MR27D-SR1 | SFP Multi-rate SR1, 100-2700Mpbs, SM, 1310nm, 2km with Digital Diagnostics | | | | | SFP-MR27D-IR1 | SFP Multi-rate IR1, 100-2700Mbps, SM, 1310nm, 0-30km with Digital Diagnostics. | | | | | SFP-MR27D-IR2 | SFP Multi-rate IR2, 100-2700Mbps, SM,1550nm, 0-60km with Digital Diagnostics. | | | | | SFP-MR27D-LR1 | SFP Multi-rate, LR1, 100-2700Mbps, SM, 1310nm, 20-50km with Digital Diagnostics | | | | | SFP-MR27D-LR2 | SFP Multi-rate, LR2, 100-2700Mbps, SM, 1550nm, 40-112km with Digital Diagnostics | | | | | CWDM Protocol Independent (LC Connectors) | | SFP-27DCWEIR-XX | SFP Multi-rate EIR, 100-2700Mbps, SM CWDM (XX=Wavelength 1470-1610nm), 20-60 km, with Digital Diagnostics. | | | | | SFP-27DCWLR-XX | SFP Multi-rate LR, 100-2700Mbps, SM CWDM (XX=Wavelength 1470-1610nm), 40-100 km, with Digital Diagnostics. | | | | | Multi-rate 100-2700 Mbps 100GHz DWDM SFP Transceivers | | SFP-27DWLR08-XX | SFP Multi-Rate LR, 100-2700Mbps, SM DWDM (XX=ITU C-Band Channels 17-60 for 100 GHZ), 80km, with Digital Diagnostics | | | | | SFP-27DWLR12-XX | SFP Multi-Rate LR, 100-2700Mbps, SM DWDM (XX=ITU C-Band Channels 17-60 for 100 GHZ), 120km, with Digital Diagnostics | | | | | SDI SFP | | | SFP-CXDV-TX27 | Unidirectional Digital Video SFP, SMPTE 259m; (270Mbps) TX only | | | | | SFP-CXDV-RX27 | Unidirectional Digital Video SFP, SMPTE 259m; (270Mbps) RX only | | | | | 10Gbps XFP’s | | | XFP-10GD-SX | XFP 10-GbE, or 10GFC, MM, 850nm, 300M with Digial Diagnostics | | | | | XFP-10GD-MMX | XFP 10-GbE, or 10GFC, Extended MM, 1310nm, 500m with Digial Diagnostics | | | | | XFP-10GD-LR | XFP OC192/STM-64, 10GE or 10G FC, SM, 1310nm, 10km, with Digital Diagnostics. | | | | | XFP-10GD-IR2 | OC192/STM-64, 10GE or 10G FC, SM, 1550nm, 40km, with Digital Diagnotics | | | | | Specialty Patch Cables | | | Add/Drop Multiplexers | | | ADCP-XX | Single channel DSC Pluggable OADM at xx* CWDM wavelength with SC connectors | | | | | PADMSYY/XX | CWDM OADM Uni-directional Cable. YY=Conn type MU, SC, LC. XX=Wavelength | | | | | Splitter Combiner | | | PASCLCAS/3S | Cable Fiber Optic, Splitter/Combiner, w/cable assembly LC-SC/APC, 1310nm, SM | | | | | PASCLCAS/5S | Cable Fiber Optic, Splitter/Combiner, w/cable assembly LC-SC/APC, 1550nm, SM | | | | | PASCSCAS/3S | Cable Fiber Optic, Splitter Combiner w/cable assembly, SC-SC/APC, 1310nm, SM | | | | | PASCSCAS/5S | Cable Fiber Optic, Splitter Combiner w/cable assembly, SC-SC/APC, 1550nm, SM | | | | | 2 Wavelength CWDM | | | PASCSC/3155 | Cable , Protocol Independent Single Fiber TX:1310, RX:1550nm with SC Connectors in AB Box | | PAWLCSC/5559 | Cable, Protocol Independent Single Fiber TX:1550, RX:1590nm, SC-common port, LC-add/drop & reflect port in AB box | | PAWSC/5559 | Cable, Protocol Independent Single Fiber TX:1550,RX:1590nm, SC Connector in AB Box | |